Microneedle Patch Tracks Postsurgical Troponin Continuously
A microneedle patch measuring cardiac troponin continuously in interstitial fluid has shown proof of concept in mice, targeting silent MINS in the 20% of high-risk patients affected after surgery.

A wearable patch that continuously measures cardiac troponin in interstitial fluid for several days has been demonstrated in mouse models of heart disease, with researchers at McMaster University positioning it as an answer to silent myocardial injury after noncardiac surgery. The findings were published in Science Advances (Zheng et al., 2026; DOI: 10.1126/sciadv.aej0899).
The device pairs microneedle sampling with a hybrid antibody–aptamer biosensor. It targets a well-defined clinical gap: roughly 300 million people undergo noncardiac surgery each year, and same-day discharge is increasingly routine, yet the immediate postoperative window carries elevated cardiac risk.
Why MINS is the target
About 20% of higher-risk patients experience myocardial injury after noncardiac surgery (MINS, ischemic myocardial damage detected by troponin elevation without necessarily meeting infarction criteria). Most cases produce no symptoms and no ECG changes.
"About 90% of these cases are silent. The only way to diagnose many of them is through a blood test, which is difficult when patients are already home," said Leyla Soleymani, professor of engineering physics and lead of engineering innovation at NexusHealth.
"We wanted to develop a way to continuously monitor for heart injuries without requiring repeated blood draws."
Serial troponin measurement is standard in-hospital practice. After discharge, it effectively stops. The patch attempts to close that gap.
How the sensor works
The engineering problem is hard for a specific reason. Continuous monitoring already exists for small molecules such as glucose, but proteins are far harder to track. Cardiac troponin circulates at very low concentrations and becomes further diluted in interstitial fluid, the liquid surrounding cells beneath the skin.
The device solves sampling and sensing separately:
- Microscopic polymer microneedles penetrate only the outer skin layers, avoiding nerves and blood vessels, and collect interstitial fluid painlessly over extended periods.
- The fluid reaches a biosensor combining antibodies, which recognize the target protein, with aptamers (short engineered DNA or RNA strands that bind specific biological targets and generate a measurable signal).
- A mechanism continuously refreshes the sensor surface, allowing tracking of troponin levels over several days rather than a single readout.
"That's what makes this such an important advance. We're monitoring a protein that's present at very low levels and doing it continuously in living tissue," Soleymani said.
Earlier iterations of the platform from her group tracked smaller molecules such as lactate. "A lot of different pieces had to come together for this work. We had to develop new sensing strategies, create a way to continuously refresh the sensor and integrate everything into a device patients could comfortably wear," she said.
Who built what
The project spans several institutions. Researchers at the University of Waterloo developed the microneedle technology enabling continuous sampling.
"Creating microneedles that can sample interstitial fluid comfortably and painlessly over extended periods and integrating them with sensing electrodes were key steps toward continuous wearable sensing," said coauthor Mahla Poudineh, now an associate professor at NYU Tandon School of Engineering, whose group pioneered these polymeric microneedles for wearable sensing.
At McMaster, coauthor Bernardo Trigatti, professor in the Department of Biochemistry and Biomedical Sciences and senior scientist at the Thrombosis and Atherosclerosis Research Institute of Hamilton Health Sciences and McMaster University, led testing in living systems.
"Testing the device in mouse models of heart disease was an important step toward understanding how it could eventually perform in clinical settings," Trigatti said.
What does this change for clinicians?
Right now, nothing. This is preclinical proof of concept in mice, not a validated diagnostic. There is no regulatory clearance, no established analytical performance in humans, and no data on whether patch-based continuous troponin monitoring would change post-discharge management or outcomes in MINS patients. The team plans additional testing, and commercialization is being pursued through Aptec Health, a startup founded to develop the technology.
The credible medium-term scenario, if human validation succeeds, is a monitoring tool for the post-discharge window in higher-risk surgical patients — a population where MINS is common, largely silent, and currently invisible to standard follow-up. The McMaster group notes its institution's established research leadership in postoperative myocardial injury as the clinical foundation for the work.
Soleymani frames the ambition more broadly: many significant health changes occur between clinic visits, and continuous protein sensing could extend beyond troponin.
"The future of medicine is personalized, and personalized medicine needs data," she said. "I like working on hard problems, and I like working on meaningful problems. This one has both.
Source: Medical Xpress
More from James Calloway
Show full bio
News editor covering regulation, policy and their impact on Doctors' Insider is a professional daily at Doctors' Insider.
68 articles
Related articles
- Neural Network Reads ICD Signals to Predict Ventricular Fibrillation
- Lubdub's 14-day ECG patch enters clinical trial in Perth with 18x cleaner signal
- Aficamten reduces LV mass and wall thickness in nonobstructive HCM
- Sepsis AI Cut Mortality 18.7%; a Blanket Slowdown Would Protect Diagnostic Error
- FDA Puts Head-to-Head MAPLE-HCM Data Into Aficamten Label